  Datasheet File OCR Text:
  power hicorder recorders 8714 -01 ,8715 -01 introducing easy-to-use power monitoring recorders! see what youve been missing ! capture spikes, sags, and surges monitor and record power anomalies and fluctuations easily, even unattended analyze leakage currents as well as ac/dc current up to 2000 amps true-rms with trigger function 250 sec transient waveform capture do you ever worry about power failure?
2 [ setup ] measurement mode is set to waveform, time axis to 2ms. recording length is set to 20 division. [ channel setup ] for current waveforms, after selecting a clamp-on probe for the input type from mode, select the range of the clamp. here, we select 9010 and 100a. set the range of the clamp-on probe in the same way. [ starting measurement ] clamp the probe around the conductor to be measured. press the start button. the current waveform is displayed on the screen. to stop measuring, press the stop button. what a power recorder does simple setup there are many power-quality concerns in today's pc-based businesses, and detecting power anomalies is important for maintaining factory facilities and equipment. the power hicorder s 8714 -01 and 8715 -01 are monitoring recorders that can capture instantaneous power drop-outs, brown-outs, spikes and sags, and record voltage changes with simple operation, and even monitor and record while totally unattended. the compact b5 size and 1.5kg (52.9oz.) weight provide excellent portability among worksites. ( 8714 -01 ) 1. simple setup. no worries about operability. 2. accepts direct input of line voltages up to 400 v, and up to 1000 v ac/ 2000 v dc with the use of the differential probe 9322 accessory. 3. voltage and current can be simultaneously measured on four isolated channels. 4. data immediately before an anomaly occurs can be stored and recorded. 5. high quality data printouts on site. 6. high-speed a/d converter stores data in memory, providing simple recording of events that cannot be recorded by a pen recorder. 7. two measurement functions are available: waveform measurement mode (memory mode), and rms trend measurement mode (rms recorder & memory). 8. hioki clamp-on probes (voltage- output type) can be directly connected. example to monitor the current waveform on a 220 v power line. current waveform example measured. press the start button. the current waveform is displayed on the screen. to stop measuring, press the stop button. current waveform example record power anomalies accurately with simple operation ! - aplications -
 two models: the two-channel (8714-01) and four-channel (8715-01) - specifcations - basic specifications 8714 -01 8715 -01 measurement mode waveform measurement mode (power waveform observation) , rms trend measurement mode (rms observation) input types and number of channels input channels fixed, analog 2 channels inter-channels and input-frame isolation input channels fixed, analog 4 channels inter-channels and input-frame isolation maximum sampling rate 400k sample/s (2.5s period) simultaneous sampling for 2 or 4 analog channels memory capacity continuous 2-channels measurement (12-bit analog) 64 kilo-words/ ch continuous 4-channels measurement (12-bit analog) 64 kilo-words/ ch external memory pc card type i i slot 1 : flash ata card (max.1 gb), ms-dos format. memory contents : settings data, measurement data (binary or text format), screen data (bmp) backup function clock, waveform data and settings, battery life approx. 5 years (at 25c/ 77f). external control terminal block : trigger input/output environment conditions (no condensation) operation: +5c/41f to +40c/104f, 35% to 80% relative humidity. storage: -10c/14f to +50c/122f, 35% to 80% relative humidity. applicable standards safety: en61010 emc: en61326, en61000-3-2, en61000-3-3 power supplies (1) ac adapter model 9418 -15 or 9418 -10 (dc 12v 10%) (2) battery pack 9447 (ac adapter has priority when used in combination with battery pack, fast recharge possible with ac adapter) power consumption 15va max. continuous operation time approx. 3 hours (with battery pack 9447 , trigger standby at 23c/ 73f) charge time approx. 2 hours fast charge with power switch off (at 23c/ 73f) dimensions and mass approx. 280 (11.02) w 170 (6.69) h 52 (2.05) dmm (inch), 1.5kg/ 52.91oz (without batteries) approx. 280 (11.02) w 170 (6.69) h 52 (2.05) dmm (inch) , 1.6kg/ 56.44oz (without batteries) supplied accessories instruction manual 1, measurement guide 1, recording paper 1, paper attachment 2, blank box 1, strap 1, ac adapter 9418 -15 1, connection cord 9197 2 (8714-01) , 4 (8715-01) , application disk 1 waveform measurement (power waveform observation) mode time axis 200 and 400 s, 1, 2, 5, 10, and 20ms/division, time axis zoom 2 to 10; 3 settings, compression 1/2 to 1/50; 5 settings sampling period 1/80 of time axis ranges (minimum sampling period 2.5 s) recording length 20, 50, 100, 200, or 400 division (800 division at sequential save off) pre-trigger can record data from before the trigger point, 0/10/20/50, or 100% of recording length other functions voltage axis normal (1/2), magnified (1), left-right waveform scrolling, automatic, manual and partial (between a-b cursors) printing other functions general printing of settings including input range, trigger time, etc., cursor measurement, start condition retention, auto setup, list & gauge printing, power-save function, dmm function (voltage shown as numerals on the display) , auto saving, partial saving (between a-b cursors or all data) , sequential save. dmm function display update rate: 1 second display contents: rms value (only measuring dc and 50/60hz) display digit: 4 (last digit 0 to 4 is rounded zero, 5 to 9 is rounded five) voltage ranges: auto-select only (five ranges from 10 mv to 100 v/ div.) accuracy: 3% rdg. 5dgt. input section (accuracy at 23 5 ?c/73 9 ?f after 30 minutes warm-up time; accuracy guaranteed for 1 year) input isolated bnc terminal, input item: voltage, 9010, 9018, 9132, 3283, 3284, 3285, 9322 (selectable) measurement range voltage : 100, 200, 400v line, or 100v dc 9010 : 10, 20, 50, 100, 200, or 500a 9018 : 10, 20, 50, 100, 200, or 500a 9132 : 20, 50, 100, 200, 500, or 1000a 3283 : 10ma, 100ma, 1, 10, or 200a 3284 : 20 or 200a 3285 : 200 or 2000a 9322 : 400 or 600v line max. sampling rate 400ks/s (simultaneous sampling of all channels) accuracy, frequency characteristics 0.5% f.s. (applied accuracy of clamp-on probe) , dc to 50khz 3db low-pass filter off, 500hz, 5khz input resistance and capacitance 1m, 7pf approx. (at 100khz) input coupling dc (fixed) max. allowable input 450v ac rms, dc cat i i (upper voltage which when applied to between input pins does not damage them) max. rated voltage to earth 450v ac rms, dc (upper voltage which when applied to input channel casing or between input channels does not damage them) recording and display section display 5.7-inch stn color lcd, with english/japanese language selector 240 320 dots recording paper 112mm (4.41in) 18m (59.06ft), thermal paper roll recording area 100mm in full scale (10 divisions), 1 division = 10mm (0.39in) recording speed max. 1sec/division (with ac adapter use) trigger function (only for anomalous waveform measurement and instantaneous power fluctuation recording) trigger source analog input ch1 - ch4 ( 8714-01 : ch1 - ch2) , external (either on or off for each source) , logical and/or of sources anomalous waveform triggers level trigger: at preset voltage level, on either rising or falling edge window trigger: at entry or exit from preset upper and lower limits voltage drop trigger: especially for 50/60hz commercial power, when peak voltage falls below preset value period trigger: when period of rising or falling edge of measured signal exceeds preset period waveform judgment trigger: especially for 50/60hz commercial power, to monitor signals outside of judgment range in real time (when time axis range 20ms/division is not applicable) power fluctuation measurement triggers (valid only when instantaneous waveform measurement is enabled) voltage drop trigger: especially for 50/60hz commercial power, when peak voltage falls below preset value rms level trigger: at preset effective value, on either rising or falling edge rms window trigger: at entry or exit from preset upper and lower limit levels pre-trigger 0, 10, 20, 50, 100% (for anomalous waveform measurement, instantaneous power fluctuation recording) level setting resolution 0.25% f.s. (f.s.=10 divisions, 0.1% f.s. for use with waveform judgment trigger) trigger filter off/on (0.5 divisions fixed filter width) rms trend measurement (rms fluctuation measurement) mode measurement objective commercial mains power (50/60hz) time axis 1/2/5 seconds/div (cannot realtime print); 10/30 seconds; 1/2/5/10/30 minutes; or 1hour/div, time axis compression 1/2 to 1/50; 5 settings sampling period 250 s fixed (rms value 800 data/second) recording length continuous measurement only (up to 200 division of data are stored internally) rms accuracy 3 % f.s. waveform display area 100v line: 75 to 125v rms (standard) 200v line: 150 to 250v rms (standard) 400v line: 275 to 525v rms (standard) clamp: 0a rms to f.s.value on clamp-on probe (rms) 9322 differential probe: 400v line; 275 to 525v rms (standard) 9322 differential probe: 600v line; 475 to 725v rms (standard) other functions voltage axis normal (1/2), magnified (5), left-right waveform scroll, automatic, manual and partial (between a-b cursors) printing, hybrid recording: prints logging data for each division together with waveform rms trend measurement (instantaneous waveform measurement) mode time axis 200 and 400 s, 1, 2, 5, 10, and 20ms/division, time axis zoom 2 to 10; 3 settings, compression 1/2 to 1/50; 5 settings sampling period 1/80 of time axis ranges (minimum sampling period 2.5 s) recording length 20, 50, 100, or 200 division (400 division at sequential save off) pre-trigger can record data from before the trigger point, 0/10/20/50, or 100% of recording length other functions voltage axis normal (1/2), magnified (1), left-right waveform scroll mass (8714 -01 ) : approx. 1.5kg/52.91oz mass (8715 -01 ) : approx. 1.6kg/56.44oz 170 mm (6.69 in ) 280 mm (11.02 in ) 52 mm (2.05 in)
head office : 81 koizumi, ueda, nagano,  86-1192, japan tel +81-268-28-0562 / fax +81-268-28-0568 e-mail: os-com@hioki.co.jp hioki usa corporation : 6 corporate drive, cranbury, nj 08512 usa tel +1-609-409-9109 / fax +1-609-409-9108 e-mail: hioki@hiokiusa.com distributed by all information correct as of jan. 25, 2007. all specifcations are subject to change without notice. 8714e4-71e-00p printed in japan shanghai representative offce : 1  10 shanghai times square offce 9  huaihai zhong road shanghai, 200021, p.r.china tel +86-21-6  91-0090, 0092 fax +86-21-6  91-0  60 e-mail: info@hioki.cn 4 input from power-concent power hicorder 8714 -01 (2ch model) power hicorder 8715 -01 (4ch model) carrying case 9648 hard case type, for storing options paper winder 220h paper width: 70 to 220 mm, using special-purpose ac adapter recording paper 9234 18 m/ 59.06 feet length, 10 rolls/ 1 set carrying case 9391 soft case type, for storing options holds more options than the 9648 hard case included accessories: ac adapter 9418 -15 1, recording paper 1, blank box 1, strap 1, connection cord 9197 ( 8714 -01 : 2, 8715 -01 : 4), application disk 1 clamp on probe 9018 -10 input from 10 to 500a 40hz to 3khz for 0.2v ac output. bnc terminal clamp on probe 9132 -10 input from 20 to 1000a 40hz to 1khz for 0.2v ac output. bnc terminal line splitter ct10 1 a for 100 v / 15a, convenient for measuring 100v ac line current with clamp-on probe composition of options note: product names appearing herein are trademarks or registered trademarks of various companies. connection cord 9217 insulation bnc-to-insulation bnc, use to connect to insulation-bnc terminal on input module connection cord 9197 for up to 500v, 1.5 m length concent input cord 9448 use for 100v commercial line, 2m length wave processor 9335 data conversion, print functions, waveform display, compatible with windows 95/98/me, windows nt 4.0/2000/xp pc card 128m 9726 (128mb capacity) pc card 256m 9727 (256mb capacity) pc card 512m 9728 (512mb capacity) pc card 1g 9729 (1gb capacity) supplied with pc card adapter conversion adapter 9199 banana-to-bnc, use to connect to insulation-bnc terminal on input section clamp on ac/dc hitester 3284 20a or 200a ac/dc, with analog output of 1v f.s. dc, and waveform monitor output of 1v f.s. ac at 10hz to 2khz, or dc. requires the ac adapter 9445 -02 / -03 clamp on leak hitester 3283 for leakage current measurement, includes 10ma to 200a ranges, with analog output of 1v f.s. dc, and waveform monitor output of 1v f.s. ac at 40hz to 2khz. requires the ac adapter 9445 -02 / -03 battery pack 9447 7.2v, 2400mah charge stand 9643 independent of main unit the 8714 -01 /8715 -01 , use with the ac adapter 9418 -15 to charge one model battery pack 9447. ac adapter 9418 -15 universal 100 to 240 v ac, 12 v dc/ 2.5 a output ac adapter 9445 -02/-03 use for the 3283, 3284, 3285 , for usa/csa 9445 -02 , for eu 9445 -03 output cord 9094 required along with the 9199 adapter to connect the 3283/3284/3285 to the 8714 -01 or 8715 -01 conversion adapter 9199 banana-to-bnc, use to connect to insulation-bnc terminal on input section + clamp on ac/dc hitester 3285 200a or 2000a ac/dc, with analog output of 1v f.s. dc, and waveform monitor output of 1v f.s. ac at 10hz to 1khz, or dc. requires the ac adapter 9445 -02 / -03 ac adapter 9418 -15 use for the 9322 , 100 to 240 v ac differential probe 9322 for inputs up to 2kv dc or 1kv ac, the 9322 requires the ac adapter 9418 -15 1kv ac, 2kv dc input up to 450v ac input record current waveform record current waveform pc card precaution u s e o n l y p c c a rd s s o l d b y h i o k i . c o m p a t i b i l i t y a n d p e r f o r m a n c e a re n o t guaranteed for pc cards made by other manufacturers. you may be unable to read from or save data to such cards. not ce certified not ce certified not ce certified not ce certified input cords of included accessories are the 9197 only. for current measurement, please purchase the optional clamp-on probe, or clamp-on tester. + combination example: 2-channels, with current measurement main unit paper battery pack current up to 500a carrying case model number quantity 8714 -01 1 92 41 (10 rolls) 94471 9018 -10 2 9911 combination example: 4-channels, with current measurement main unit paper battery pack current up to 500a carrying case model number quantity 8715 -01 1 92 41 (10 rolls) 94471 9018 -10 4 9911